     54The on-board backup power source for the NVRAM is a Sanyo CR14250SE lithium battery which is socketed for easy removal and replacement. A small capacitor is provided to allow the battery to be quickly replaced without data loss.
     55
     56The lifetime of the battery is very dependent on the ambient temperature of the board and the power-on duty cycle. At 70°C, the
     57worst-case elapsed time for battery protection is 7 years. Battery warning time is 24 hours minimum. At lower ambient temperatures
     58the backup time is greatly extended.
     59
     60When a board is stored, the battery should be disconnected to prolong battery life. This is especially important at high ambient
     61temperatures. The MBX board is shipped with the on-board battery disconnected (i.e., with a jumper installed across J1 pins 2 and 3). If
     62you intend to use the battery as a backup power source, it is necessary to reconfigure the jumpers on J1 and J2 before installing