#805 closed defect (fixed)

It is not possible to create more than 11 posix timers

Reported by: nuno-costa Owned by: Joel Sherrill
Priority: normal Milestone: 2
Component: score Version: 4.6
Severity: major Keywords:
Cc: bugs@… Blocked By:
Blocking:

Description

RTEMS didn't allow one to create more than 11 posix timers

Release:
RTEMS v4.6.2

Environment:
Intel celeron mendocino at 400MHz
Linux Mandrake 9.2
target i386, bsp=PC686

How-To-Repeat:
Simply create a posix app which creates 20 posix timers and in the 12th timer the system says EAGAIN. This happens even one configured 100 or 1000 timers in the configuration file.

Attachments (1)

pr805.diff (964 bytes) - added by nuno-costa on 12/03/06 at 13:31:13.
pr805.diff

Download all attachments as: .zip

Change History (2)

comment:1 Changed on 08/17/05 at 21:58:12 by Joel Sherrill

Status: assignedclosed

State-Changed-From-To: open->closed
State-Changed-Why: Attached patch (pr805.diff) applied to 4.6 branch and CVS trunk.

Changed on 12/03/06 at 13:31:13 by nuno-costa

Attachment: pr805.diff added

pr805.diff

Note: See TracTickets for help on using tickets.