#792 closed defect (fixed)

Internal errors before user extension initialization

Reported by: jacques.seronie-vivien Owned by: Joel Sherrill
Priority: low Milestone: 4.11
Component: score Version: 4.6
Severity: major Keywords:
Cc: bugs@…, sebastian.huber@… Blocked By:
Blocking:

Description

If an error is detected before the user extension initialization (for example during the executive workspace initialization), RTEMS does not perform as expected a clean halt, but instead loops infinitely when it tries to retrieve the fatal error user extension entry point (at this time, this table content is not initialized).

Release:
4.6.1

Environment:
build with solaris tools, sparc-rtems target, erc32 bsp

Change History (3)

comment:1 Changed on May 20, 2005 at 1:13:59 PM by Joel Sherrill

Status: assignedwaiting

comment:2 Changed on Nov 22, 2012 at 2:50:31 PM by Sebastian Huber

Cc: Sebastian Huber added
Milestone: 24.11
rep_platform: All

comment:3 Changed on Nov 22, 2012 at 3:00:50 PM by Sebastian Huber

Resolution: fixed
Status: assignedclosed

Fixed.

Note: See TracTickets for help on using tickets.