Description

The update fixes breakage of TMS570 support after Alexander Krutwig
switch of RTEMS time read to timecounter mechanism

bsps: Convert clock drivers to use a timecounter

The TMS570 BSP is new BSP which appears first in 4.11 RTEMS release.

Without fixing the time read is scaled about 60 times wrong to real time and task related delay functions.

Attachments (1)

0001-bsp-tms570-fix-get-time-resolution-after-infrastruct.patch (4.0 KB) - added by Pavel Pisa on 07/16/15 at 13:25:00.

Download all attachments as: .zip

Change History (2)

comment:1 Changed on 09/10/15 at 08:38:48 by Pavel Pisa

Resolution: fixed
Status: newclosed