Changeset 77ff3d10 in rtems for c/src/ada-tests/sptests/sp04


Ignore:
Timestamp:
Jun 2, 1997, 10:14:51 PM (24 years ago)
Author:
Joel Sherrill <joel.sherrill@…>
Branches:
4.10, 4.11, 4.8, 4.9, 5, master
Children:
7f79b673
Parents:
cf1ced66
Message:

removed configuration table definition in Ada

File:
1 edited

Legend:

Unmodified
Added
Removed
  • c/src/ada-tests/sptests/sp04/sptest.ads

    rcf1ced66 r77ff3d10  
    115115   );
    116116
    117 --
    118 --  This is the User Extension Table for this test.
    119 --
    120 
    121    EXTENSIONS : aliased RTEMS.EXTENSIONS_TABLE :=
    122    (
    123         NULL,                                        -- Task create
    124         NULL,                                        -- Task start
    125         NULL,                                        -- Task restart
    126         NULL,                                        -- Task delete
    127         SPTEST.TASK_SWITCH'ACCESS,                   -- Task switch
    128         NULL,                                        -- Task begin
    129         NULL,                                        -- Task exitted
    130         NULL                                         -- Fatal error
    131    );
    132 
    133 --
    134 --  This is the Driver Address Table for this test.
    135 --
    136 
    137    DEVICE_DRIVERS : aliased RTEMS.DRIVER_ADDRESS_TABLE( 1 .. 1 ) :=
    138    (1=>
    139       (
    140         CLOCK_DRIVER.INITIALIZE'ACCESS,              -- Initialization
    141         RTEMS.NO_DRIVER_ENTRY,                       -- Open
    142         RTEMS.NO_DRIVER_ENTRY,                       -- Close
    143         RTEMS.NO_DRIVER_ENTRY,                       -- Read
    144         RTEMS.NO_DRIVER_ENTRY,                       -- Write
    145         RTEMS.NO_DRIVER_ENTRY                        -- Control
    146       )
    147    );
    148 
    149 --
    150 --  This is the Initialization Tasks Table for this test.
    151 --
    152 
    153    INITIALIZATION_TASKS : aliased RTEMS.INITIALIZATION_TASKS_TABLE( 1 .. 1 ) :=
    154    (1=>
    155      (
    156        RTEMS.BUILD_NAME( 'U', 'I', '1', ' ' ),        -- task name
    157        2048,                                          -- stack size
    158        1,                                             -- priority
    159        RTEMS.DEFAULT_ATTRIBUTES,                      -- attributes
    160        SPTEST.INIT'ACCESS,                            -- entry point
    161        RTEMS.NO_PREEMPT,                              -- initial mode
    162        0                                              -- argument list
    163      )
    164    );
    165 
    166 --
    167 --  This is the Configuration Table for this test.
    168 --
    169 
    170    CONFIGURATION : aliased RTEMS.CONFIGURATION_TABLE := (
    171       RTEMS.NULL_ADDRESS,        -- will be replaced by BSP
    172       64 * 1024,                 -- executive RAM size
    173       10,                        -- maximum # tasks
    174       0,                         -- maximum # timers
    175       0,                         -- maximum # semaphores
    176       0,                         -- maximum # message queues
    177       0,                         -- maximum # messages
    178       0,                         -- maximum # partitions
    179       0,                         -- maximum # regions
    180       0,                         -- maximum # dp memory areas
    181       0,                         -- maximum # periods
    182       1,                         -- maximum # user extensions
    183       RTEMS.MILLISECONDS_TO_MICROSECONDS(10), -- # us in a tick
    184       100                        -- # ticks in a timeslice
    185   );
    186 
    187117end SPTEST;
Note: See TracChangeset for help on using the changeset viewer.