1@c
2@c  COPYRIGHT (c) 1988-1998.
3@c  On-Line Applications Research Corporation (OAR).
4@c  All rights reserved.
5@c
6@c  $Id$
7@c
8
9@chapter Default Fatal Error Processing
10
11@section Introduction
12
13Upon detection of a fatal error by either the
14application or RTEMS the fatal error manager is invoked.  The
15fatal error manager will invoke the user-supplied fatal error
16handlers.  If no user-supplied handlers are configured,  the
17RTEMS provided default fatal error handler is invoked.  If the
18user-supplied fatal error handlers return to the executive the
19default fatal error handler is then invoked.  This chapter
20describes the precise operations of the default fatal error
21handler.
22
23@section Default Fatal Error Handler Operations